Autogard Series E-220 Digital Power Monitor

E-220 Options
All E-220 power monitors measure and display real-time Power, % Load, RMS voltage, RMS current and Power Factor. Types 1 to 4 have relays which can be programmed to trip at selected power levels. Transducer versions (Types 5 and 6) are also available which provide the power as a digital or analogue output for use with external control and monitoring equipment. Other types are available with alternative relay configirations to meet your specific requirements. Please consult Autogard.

 

Type 1 - Single relay, one overload trip
One overload level can be programmed to trip the single relay at the desired power level. The relay is held closed in normal operation and latches open on trip. (ie. N.O. contact which fails safe on loss of power).

Type 2 – 2 relays, one overload trip, one underload trip
This is the most commonly used, general purpose option. In addition to an overload trip, there is an underload limit which can be used to give warning of loss of load due to a process failure or other system abnormality. Each trip has its own fail safe relay which is normally held closed and latches open on trip.

Type 3 – 2 relays, one overload warning, one overload trip
This is another commonly used configuration, where it is desirable, for example, to have a warning indication prior to an overload trip. In this case relay 1 is normally open (NO) and non-latching for use with an alarm. Relay 2 is held closed and latches open on trips for fail safe motor shut down.

Type 4 – 2 relays, 2 independent overload trips
This option is primarily intended for dual mode operation
(e.g. 2-speed motors) where separate trip levels are required for
2 different running conditions. Only one trip is active at a time and each has its own latching relay. The relays are normally held closed and latch open on trip. The active trip is selected using a 12-24V DC signal to IN2.


Type 5 – Analogue outputs, 0-10V and 4-20mA
Terminals on the front panel provide analogue outputs which are proportional to the power level in real time. Both 0-10V and 4-20mA connections are provided. The outputs can be used for monitoring, analysis or control purposes. This version does not include any trips or relays.

Type 6 – Digital output, RS485 in ASCII
This version is similar to the Type 5 but is used when a digital signal is preferred. The unit outputs an ASCII character string, denoting the power values in real time. Refer to the installation data sheet for details of format. As with Type 5, this version does not include any trips or relays.

Voltage Ranges
The E-220 is suitable for use with motor voltages between 380 and 460V AC 3-phase. For 575V AC please specify model E-221. Type and frequency options are the same as for E-220. For other voltages, please consult Autogard.

Current Ranges
The E-220 measures current using an internal Current Transformer (CT). This is suitable for 380/460V motors up to 18.5kW (25HP). For larger motors, an external current transformer is also required – please request "External CT 300A/5A" when ordering. For other motor voltages, or power ratings over 220kW (300HP), please consult Autogard.

 

Ordering Example

Autogard Power Monitor E-220/50-3

Autogard Model E-220, 380/460V, factory set for 50Hz AC 3-phase mains operation, Type 3.